BMA antirust
Primer option for metal substrates.

A one-component, air-drying synthetic alkyd-based coating that offers a durable, fast-drying solution for interior and exterior superstructures, as well as steel surfaces.
ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015
BMA Industrial Paint Synthetic is a one-component, air-drying synthetic alkyd-based coating. It offers a durable, fast-drying solution suitable for both interior and exterior superstructures, as well as steel surfaces. The paint provides superior adhesion and outstanding resistance to weathering, cracking, abrasion and mechanical stress.
Data for BMA Industrial Paint Synthetic 1BM-PSI:
| Parameter | Norm / standard | Result |
|---|---|---|
| Total Solids, by weight (%) | ASTM D1259 | 67.29 |
| Total Solids, by volume (%) | ISO 3233 | 55 |
| Viscosity at 25 °C (Poises) | ASTM D562 | 20 |
| Specific Gravity (g/cm³) | ASTM D1475 | 1.2±0.01 |
| Total Volatile Organic Compound (VOC) (g/L) | ASTM D3960 | 393.01 |
| Theoretical Spreading Rate (m²/L) | — | 16.4 |
| Recommended WFT (µm) (2) | — | 100–120 |
| Recommended DFT (µm) (1) | — | 50–60 |
| Appropriate solvent | — | BMA White Spirit |
| Solvent ratio by volume (%) | — | 20–25 |
| Gloss Levels | — | Glossy, Matt, Semi-Matt & 30% glossy |
Before applying BMA Industrial Paint Synthetic, complete all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.
For new steel, clean any oil or grease residues from the surface using SAMA chemical 3 in 1 phosphating additive (1L:35L water). Sand the substrate to Sa 2½ until smooth, then remove all sanding dust and let it dry before applying any primer. For painted steel, remove loose and peeling paint by mechanical methods such as sanding or sandblasting the entire surface until smooth, so the new coating can adhere properly. When the old paint is compatible with the new one, only light sanding is required. Then remove persistent dirt, sanding residues and zinc salts with a detergent solution and water. For non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.), remove corrosion residues and, to promote adhesion of the subsequently applied coatings, use a thin layer (8–10 µm) of BMA Wash Primer to etch the substrate. If the surface is unetched or etching is not possible, sweep or brush blast clean it with a non-metallic abrasive to lightly roughen the surface. Let the surface dry before coating application. To even out surface unevenness, apply BMA putty polyester. For corrosion prevention, prime the cleaned surface directly.
For previously painted wood, remove paint residues with a scraper to prevent the new coating from flaking if it is not compatible with the old one. Sand and smooth the surface, then clean it well and remove the sanding dust. Let the surface dry before applying any primer or sealer. For new wood, lightly sand the surface and all edges until smooth. Apply BMA insulator on oily wooden substrates. Thinning of 10–15% is required for faster solvent evaporation. Then use NC Putty or BMA Bouche Pores to close off, patch and fill all surface imperfections (cracks, holes, pores, etc.). Clean the substrate and let it dry, then make sure the moisture content does not exceed 10%. Sand until smooth using 300-grit sandpaper. Clean it well before any coating application.
Metal substrates can be primed before applying BMA Industrial Paint Synthetic, using BMA antirust, BMA Marine Primer or BMA Zinc chromate primer. Priming must be done directly after preparing, cleaning and drying the surface.
If thinning is necessary, add 20–25% thinner (air spraying, brush or roller) to obtain the required viscosity of the mixture.
BMA Industrial Paint Synthetic should be applied in a well-ventilated area where the humidity does not exceed 75% and the temperature is between 5 °C and 35 °C. It must be applied on a clean, dry surface using a brush, roller or airless spraying system. Two coats of BMA Industrial Paint Synthetic can be applied on steel surfaces when required. If needed, it can be overcoated with a layer of BMA Varnish.
The products this coating is specified alongside in the data sheet.
Primer option for metal substrates.
Primer option for metal substrates.
Primer option for metal substrates.
Evens out surface unevenness on metal.
Closes off, patches and fills surface imperfections in new wood (cracks, holes, pores, etc.).
BMA Nitrocellulose (NC) PuttyAlternative to NC Putty for filling surface imperfections in new wood.
BMA Bouche-PoresA thin layer (8–10 µm) etches non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.) to promote adhesion.
View in catalogA layer can be applied over BMA Industrial Paint Synthetic, if needed.
BMA Varnish SyntheticCleans oil or grease residues from new steel, diluted 1L:35L water.
Applied on oily wooden substrates.
Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.
Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.
Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.
Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.
Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.
The theoretical spreading rate is 16.4 m² per liter at the recommended dry film thickness of 50–60 µm.
Apply it in a well-ventilated area, with humidity no higher than 75%, and at a temperature between 5 °C and 35 °C.
Tell us your project and volumes — our export team replies with pricing and lead times.