BMA PU Acrylic Paint container

BMA PU Acrylic Paint

Product code 1BM-PAK·Catalog name: Acrylic Paint

A two-component PU acrylic modified to highly resist UV light and aggressive environmental and marine conditions. Anti-yellowing and very durable, for industrial and offshore projects.

C5 · ISO 12944-6:2018Two-componentBrush · Roller · Airless spray

Also in: Floor Coatings, Wood

ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015

Key specifications

Coverage10.08–16.8m²/L, theoretical
Dry film30–50µm recommended
Touch dry30 min–2 hsurface touch dry
Recoat8–12 hdry to over coat
Pot life90 minafter mixing at 23 °C
VOC418.4g/L

What it's used for

Commercial, architectural and structural steelwork
Bus and truck body painting
Refineries and power plants
Offshore steelwork
C5 · ISO 12944-6:2018

Approved anti-corrosive topcoat for C5 environments, as per ISO 12944-6:2018, to be applied with a suitable intermediate coat and primer. See the system →

  • Versatile: can be used in various applications.

About BMA PU Acrylic Paint

BMA PU Acrylic Paint is a two-component, PU acrylic-based paint modified to highly resist UV light and aggressive environmental and marine conditions. It is also ideal for withstanding physical and chemical stress. In addition to its weathering resistance, it is anti-yellowing and very durable. BMA PU Acrylic Paint is your ideal solution for any industrial or offshore project.

Performance

  • Withstands chemical and physical environments
  • Great gloss retention
  • Non-yellowing
  • Great chemical and physical resistance
  • Ideal for exposure to aggressive environmental or marine conditions
  • Withstands direct sunlight
  • Long-term performance
  • Easily recoatable
  • Bonds easily to epoxy systems
  • Outstanding UV resistance
  • Long-term protection for 15 years and more

Technical specifications

Data for BMA PU Acrylic Paint cross linked with its hardener 1BM-HSP

ParameterNorm / standardResult
Total Solids, by weight (%) ASTM D236951
Total Solids, by volume (%) ISO 323350.42%
Viscosity at 25 °C (Poises) ASTM D56210
Specific Gravity (g/cm³) ASTM D14751.3
Total Volatile Organic Compound (VOC) (g/L) ASTM D3960418.4
Theoretical Spreading Rate (m²/L) —10.08–16.8
Recommended WFT (µm) (2) —60–100
Recommended DFT (µm) (1) —30–50
Appropriate solvent —BMA Thinner PU
Solvent ratio by volume (%) —20–25
Pot Life at 23 °C (minutes) ISO 9514:200590
Hardener percentage by volume (%) —25
  • (1) DFT: Dry Film Thickness
  • (2) WFT: Wet Film Thickness

How much do you need?

Coats
123
You'll need about6.0–9.9 LTheoretical spreading rate 10.08–16.8 m²/L at the recommended 30–50 µm dry film

Mixing — two-component

Add 25% hardener by volume.

Stand after mixing
4–5 minutes
Pot life
90 minutes at 23 °C
Thinner
BMA Thinner PU, 20–25% by volume

How to apply

Before you startHumidity ≤ 85%5 °C – 40 °CWell-ventilated area
1Surface preparation

Before applying BMA PU Acrylic Paint, complete all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.

2Steel surfaces

For new steel, clean any oil or grease residues from the surface using a solution of SAMAS 3in1 Phosphating Additive diluted in clean water at a ratio of 1:35. Sand the substrate to Sa 2½ until smooth, then remove all sanding dust and let it dry before applying any primer. For painted steel, remove loose and peeling paint by mechanical methods such as sanding and sandblasting the entire surface until smooth, so the new coating can adhere properly. When the old paint is compatible with the new one, only light sanding is required. Then remove persistent dirt and sanding residues with a detergent solution. For non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.), remove corrosion residues and, to promote adhesion of the subsequently applied coatings, use a thin layer (8–10 µm) of BMA Wash Primer to etch the substrate. If the surface is unetched or etching is not possible, sweep or brush blast clean it with a non-metallic abrasive to lightly roughen the surface. Let the surface dry before coating application. To even out surface unevenness, apply BMA putty polyester. For corrosion prevention, prime the cleaned surface directly.

3Priming

Priming requires a DFT of 40 µm of BMA Zinc Rich Epoxy Primer, followed by 80 µm of BMA High Build Intermediate Epoxy.

4Mixing

Pour the contents of BMA PU Acrylic Paint into a larger container, add 25% hardener by volume, mix well and wait about 4–5 minutes to sweat before application.

5Thinning

Thin with 20–25% BMA Thinner PU (THI0070) to dilute the paint for a smoother application.

6Application

Apply BMA PU Acrylic Paint in a well-ventilated area where the humidity does not exceed 85% and the temperature is between 5 °C and 40 °C. Apply by brush, roller or airless spraying system.

Drying times

  1. Surface Touch Dry30 min–2 h
  2. Dry to over coat8–12 h
  3. Full cure time4–5 days

Use it with

The products this coating is specified alongside in the data sheet.

Primer

BMA Zinc Rich Epoxy Primer

Primer, applied at a DFT of 40 µm.

Intermediate

BMA High Build Intermediate Epoxy

Intermediate coat of 80 µm, applied over the primer.

Putty

BMA putty polyester

Evens out surface unevenness on metal.

Etch primer

BMA Wash Primer

A thin layer (8–10 µm) etches non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.) to promote adhesion.

View in catalog
Hardener

Hardener

Add 25% by volume.

Thinner

BMA Thinner PU (THI0070)

20–25% to dilute the paint for a smoother application.

Cleaner

SAMAS 3in1 Phosphating Additive

Diluted in clean water at a ratio of 1:35 to clean oil or grease residues from new steel.

Packaging, colors & storage

PackagingGallon & Pail kits
ColorsColors available upon request.
Shelf life2 years from manufacturing date; Shelf life of hardener: 1 year
Storage5 °C – 35 °C, humidity ≤ 85%

Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.

Safety & compliance

Environmental Impact

Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.

Health Hazards

Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.

Safety Precautions

Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.

First Aid Measures

Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.

Certifications

This product is certified according to DIN EN ISO 12944-6:2018-06, C5-VH, Test Regime 2.
ISO 9001:2015ISO 45001:2018ISO 14001:2015
Technical data sheetTDS 287 · Edition 1
Download PDF
Common questions

Questions about BMA PU Acrylic Paint

You can apply the next coat after 8 to 12 hours. The surface is touch dry in 30 minutes to 2 hours.

The theoretical spreading rate is 10.08–16.8 m² per liter at the recommended dry film thickness of 30–50 µm.

Yes. Mix with 25% hardener by volume. The pot life is 90 minutes at 23 °C.

BMA Thinner PU, at 20–25% by volume.

Apply it in a well-ventilated area, with humidity no higher than 85%, and at a temperature between 5 °C and 40 °C.

Request a quote for BMA PU Acrylic Paint