BMA Enamel Synthetic container

BMA Enamel Synthetic

Product code 1BM-PYM, 1BM-PYT, 1BM-PYD, 1BM-PYG·Catalog name: Synthetic Enamel

A one-component, alkyd-based topcoat with quick-drying properties, for interior and exterior primed metal, wood, cementitious and plastered surfaces exposed to weathering and frequent cleaning.

Brush · Roller · Air spray

Also in: Wood

ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015

Key specifications

Coverage9.5–19m²/L, theoretical
Dry film30–60µm recommended
Touch dry4 hsurface touch dry
Recoat24 hdry to over coat
VOC350–450g/L

What it's used for

Primed wood surfaces
Gypsum surfaces
Concrete and plastered walls
Steel structures

About BMA Enamel Synthetic

BMA Enamel Synthetic is a one-component, alkyd-based topcoat with quick-drying properties. It is specially designed for use on interior and exterior primed metal, wood, cementitious and plastered surfaces exposed to various weathering conditions and frequent cleaning. BMA Enamel Synthetic is suitable for applications in industrial areas, as well as on bridges, fences, balconies, kitchens and public buildings.

Performance

  • Suitable for interior and exterior application
  • Durable, hard-wearing finish
  • Withstands weather conditions
  • Good hardness and good coverage
  • Abrasion and chemical resistance
  • Relatively quick drying
  • Withstands frequent cleaning without variation in shine, color or gloss level

Available finishes

Matt1BM-PYM
30% Glossy1BM-PYT
Demi-Matt1BM-PYD
Glossy1BM-PYG

Technical specifications

Data for BMA Enamel Synthetic for all gloss levels:

ParameterNorm / standardResult
Total Solids, by weight (%) ASTM D125968–78
Total Solids, by volume (%) ISO 323357–59
Viscosity at 25 °C (KU) ASTM D562105
Specific Gravity (g/cm³) ASTM D14751.3–1.5
Total Volatile Organic Compound (VOC) (g/L) ASTM D3960350–450
Theoretical Spreading Rate (m²/L) —9.5–19
Recommended WFT (µm) (2) —75–150
Recommended DFT (µm) (1) —30–60
Appropriate solvent —BMA White Spirit
Solvent ratio by volume (%) —15
  • (1) DFT: Dry Film Thickness
  • (2) WFT: Wet Film Thickness

How much do you need?

Coats
123
You'll need about5.3–10.5 LTheoretical spreading rate 9.5–19 m²/L at the recommended 30–60 µm dry film

How to apply

Before you startHumidity ≤ 65%Surface at least 5 °CWell-ventilated area
1Surface preparation

Before applying BMA Enamel Synthetic, complete all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.

2Metal surfaces

For new steel, clean any oil or grease residues from the surface using SAMA chemical 3 in 1 phosphating additive (1L:35L water). Sand the substrate to Sa 2½ until smooth, then remove all sanding dust and let it dry before applying any primer. For painted steel, remove loose and peeling paint by mechanical methods such as sanding or sandblasting the entire surface until smooth, so the new coating can adhere properly. When the old paint is compatible with the new one, only light sanding is required. Then remove persistent dirt, sanding residues and zinc salts with a detergent solution and water. For non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.), remove corrosion residues and, to promote adhesion of the subsequently applied coatings, use a thin layer (8–10 µm) of BMA Wash Primer to etch the substrate. If the surface is unetched or etching is not possible, sweep or brush blast clean it with a non-metallic abrasive to lightly roughen the surface. Let the surface dry before coating application. To even out surface unevenness, apply BMA putty polyester. For corrosion prevention, prime the cleaned surface directly.

3Wooden surfaces

For previously painted wood, remove paint residues with a scraper to prevent the new coating from flaking if it is not compatible with the old one. Sand and smooth the surface, then clean it well and remove the sanding dust. Let the surface dry before applying any primer or sealer. For new wood, lightly sand the surface and all edges until smooth. Apply BMA insulator on oily wooden substrates. Then use BMA Bouche-Pores to close off, patch and fill all surface imperfections (cracks, holes, pores, etc.). Clean the substrate and let it dry, then make sure the moisture content does not exceed 10%. Sand until smooth using 300-grit sandpaper. Clean it well before any coating application.

4Concrete surfaces

Prepare the concrete substrate well to avoid any coating defects. For a new surface, ensure the concrete is completely cured for at least 30 days. For both fresh and old concrete, decontamination is required to remove any dust, oil, grease, laitance, fatty acids or other contaminants. If needed, an ammonia solution can be used for thorough cleaning.

5Priming
  1. Metal surfaces: Prime the surface with a coat of BMA Antirust Primer, BMA Marine Primer or BMA Zinc chromate primer.
  2. Concrete surfaces: After cleaning, seal the surface with BMA Water Based Sealer so it is ready to receive BMA Water Based Putty Filler, then prime with BMA Undercoat.
  3. Wooden surfaces: Prime the surface with two to three layers of BMA Undercoat.
6Thinning

If thinning is required, use 10 to 15% BMA White Spirit for brush or roller application, for maximum protection of the paint's gloss level, or 10 to 20% BMA Thinner Synthetic for air spraying application.

7Application

Apply BMA Enamel Synthetic on a clean, dry surface in a well-ventilated area where the humidity does not exceed 65% and the surface temperature is at least 5 °C. Do not expose the product to mechanical stress before full curing. After applying the corresponding primer and letting it dry fully, apply two to three coats of BMA Enamel Synthetic using a brush, roller or air spraying system. It can be followed by BMA Varnish on metal and wooden surfaces, and by any type of synthetic paint for walls.

Drying times

  1. Surface Touch Dry4 h
  2. Dry to over coat24 h
  3. Thorough Dry48 h

Use it with

The products this coating is specified alongside in the data sheet.

Primer

BMA Antirust Primer

One coat to prime metal surfaces.

Primer

BMA Marine Primer

One coat to prime metal surfaces.

Primer

BMA Zinc chromate primer

One coat to prime metal surfaces.

Primer

BMA Undercoat

Primer for concrete (after sealer and putty filler) and for wood (two to three layers).

Sealer

BMA Water Based Sealer

Seals cleaned concrete so it is ready to receive BMA Water Based Putty Filler.

Putty

BMA putty polyester

Evens out surface unevenness on metal.

Putty

BMA Bouche-Pores

Closes off, patches and fills surface imperfections in new wood (cracks, holes, pores, etc.).

BMA Bouche-Pores
Putty

BMA Water Based Putty Filler

Applied on concrete over BMA Water Based Sealer, before BMA Undercoat.

Etch primer

BMA Wash Primer

A thin layer (8–10 µm) etches non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.) to promote adhesion.

View in catalog
Thinner

BMA White Spirit

10 to 15% for brush or roller application, for maximum protection of the gloss level.

View in catalog
Thinner

BMA Thinner Synthetic

10 to 20% for air spraying application.

Cleaner

SAMA chemical 3 in 1 phosphating additive

Cleans oil or grease residues from new steel, diluted 1L:35L water.

Cleaner

Ammonia solution

Can be used, if needed, for thorough cleaning of concrete.

Also

BMA insulator

Applied on oily wooden substrates.

Packaging, colors & storage

PackagingKilo, Gallon & Pail kits
ColorsAccording to BMA catalog colors.
Shelf life2 years from the manufacturing date.
Storage5 °C – 35 °C, humidity ≤ 85%

Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.

Safety & compliance

Environmental Impact

Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.

Health Hazards

Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.

Safety Precautions

Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.

First Aid Measures

Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.

Certifications

ISO 9001:2015ISO 45001:2018ISO 14001:2015
Technical data sheetTDS 36 · Edition 5
Download PDF
Common questions

Questions about BMA Enamel Synthetic

You can apply the next coat after 24 hours. The surface is touch dry in 4 hours.

The theoretical spreading rate is 9.5–19 m² per liter at the recommended dry film thickness of 30–60 µm.

BMA White Spirit, at 15% by volume.

Apply it in a well-ventilated area, with humidity no higher than 65%, and with a surface temperature of at least 5 °C.

Request a quote for BMA Enamel Synthetic

Tell us your project and volumes — our export team replies with pricing and lead times.