BMA Antirust Primer
One coat to prime metal surfaces.

A one-component, alkyd-based topcoat with quick-drying properties, for interior and exterior primed metal, wood, cementitious and plastered surfaces exposed to weathering and frequent cleaning.
Also in: Wood
ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015
BMA Enamel Synthetic is a one-component, alkyd-based topcoat with quick-drying properties. It is specially designed for use on interior and exterior primed metal, wood, cementitious and plastered surfaces exposed to various weathering conditions and frequent cleaning. BMA Enamel Synthetic is suitable for applications in industrial areas, as well as on bridges, fences, balconies, kitchens and public buildings.
Data for BMA Enamel Synthetic for all gloss levels:
| Parameter | Norm / standard | Result |
|---|---|---|
| Total Solids, by weight (%) | ASTM D1259 | 68–78 |
| Total Solids, by volume (%) | ISO 3233 | 57–59 |
| Viscosity at 25 °C (KU) | ASTM D562 | 105 |
| Specific Gravity (g/cm³) | ASTM D1475 | 1.3–1.5 |
| Total Volatile Organic Compound (VOC) (g/L) | ASTM D3960 | 350–450 |
| Theoretical Spreading Rate (m²/L) | — | 9.5–19 |
| Recommended WFT (µm) (2) | — | 75–150 |
| Recommended DFT (µm) (1) | — | 30–60 |
| Appropriate solvent | — | BMA White Spirit |
| Solvent ratio by volume (%) | — | 15 |
Before applying BMA Enamel Synthetic, complete all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.
For new steel, clean any oil or grease residues from the surface using SAMA chemical 3 in 1 phosphating additive (1L:35L water). Sand the substrate to Sa 2½ until smooth, then remove all sanding dust and let it dry before applying any primer. For painted steel, remove loose and peeling paint by mechanical methods such as sanding or sandblasting the entire surface until smooth, so the new coating can adhere properly. When the old paint is compatible with the new one, only light sanding is required. Then remove persistent dirt, sanding residues and zinc salts with a detergent solution and water. For non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.), remove corrosion residues and, to promote adhesion of the subsequently applied coatings, use a thin layer (8–10 µm) of BMA Wash Primer to etch the substrate. If the surface is unetched or etching is not possible, sweep or brush blast clean it with a non-metallic abrasive to lightly roughen the surface. Let the surface dry before coating application. To even out surface unevenness, apply BMA putty polyester. For corrosion prevention, prime the cleaned surface directly.
For previously painted wood, remove paint residues with a scraper to prevent the new coating from flaking if it is not compatible with the old one. Sand and smooth the surface, then clean it well and remove the sanding dust. Let the surface dry before applying any primer or sealer. For new wood, lightly sand the surface and all edges until smooth. Apply BMA insulator on oily wooden substrates. Then use BMA Bouche-Pores to close off, patch and fill all surface imperfections (cracks, holes, pores, etc.). Clean the substrate and let it dry, then make sure the moisture content does not exceed 10%. Sand until smooth using 300-grit sandpaper. Clean it well before any coating application.
Prepare the concrete substrate well to avoid any coating defects. For a new surface, ensure the concrete is completely cured for at least 30 days. For both fresh and old concrete, decontamination is required to remove any dust, oil, grease, laitance, fatty acids or other contaminants. If needed, an ammonia solution can be used for thorough cleaning.
If thinning is required, use 10 to 15% BMA White Spirit for brush or roller application, for maximum protection of the paint's gloss level, or 10 to 20% BMA Thinner Synthetic for air spraying application.
Apply BMA Enamel Synthetic on a clean, dry surface in a well-ventilated area where the humidity does not exceed 65% and the surface temperature is at least 5 °C. Do not expose the product to mechanical stress before full curing. After applying the corresponding primer and letting it dry fully, apply two to three coats of BMA Enamel Synthetic using a brush, roller or air spraying system. It can be followed by BMA Varnish on metal and wooden surfaces, and by any type of synthetic paint for walls.
The products this coating is specified alongside in the data sheet.
One coat to prime metal surfaces.
One coat to prime metal surfaces.
One coat to prime metal surfaces.
Primer for concrete (after sealer and putty filler) and for wood (two to three layers).
Seals cleaned concrete so it is ready to receive BMA Water Based Putty Filler.
Evens out surface unevenness on metal.
Closes off, patches and fills surface imperfections in new wood (cracks, holes, pores, etc.).
BMA Bouche-PoresApplied on concrete over BMA Water Based Sealer, before BMA Undercoat.
A thin layer (8–10 µm) etches non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.) to promote adhesion.
View in catalog10 to 15% for brush or roller application, for maximum protection of the gloss level.
View in catalog10 to 20% for air spraying application.
Can follow BMA Enamel Synthetic on metal and wooden surfaces.
BMA Varnish SyntheticCleans oil or grease residues from new steel, diluted 1L:35L water.
Can be used, if needed, for thorough cleaning of concrete.
Applied on oily wooden substrates.
Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.
Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.
Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.
Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.
Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.
The theoretical spreading rate is 9.5–19 m² per liter at the recommended dry film thickness of 30–60 µm.
BMA White Spirit, at 15% by volume.
Apply it in a well-ventilated area, with humidity no higher than 65%, and with a surface temperature of at least 5 °C.
Tell us your project and volumes — our export team replies with pricing and lead times.