BMA Polyurethane Sealer (SPU102)
Applied at a DFT of 40–60 µm, cross-linked with its hardener BMA-HPU102, directly after preparing, cleaning and drying the surface.
BMA Polyurethane (PU) Sealer
BMA Polyurethane (PU) Lacquer is a two-component polyurethane clear topcoat with weathering resistance, designed to cover surfaces with various levels of chemical and mechanical exposure. It has good application properties and must be applied over a dry, contaminant-free polyurethane sealer coat to protect the surface and provide the required gloss level.
Data for BMA PU Lacquer:
| Parameter | Norm / standard | Glossy | Demi-Matt | 30% Glossy | Matt |
|---|---|---|---|---|---|
| Total Solids, by weight (%) | ASTM D1259 | 52 | 45 | 45 | 46 |
| Total Solids, by volume (%) | ISO 3233 | 40 | 37.89 | 37.89 | 38.21 |
| Viscosity at 25 °C (Poises) | ASTM D562 | 3 | 3 | 8 | 8 |
| Specific Gravity (g/cm³) | ASTM D1475 | 1.0 ± 0.1 | 1.0 ± 0.1 | 1.0 ± 0.1 | 1.0 ± 0.1 |
| Total Volatile Organic Compound (VOC) (g/L) | ASTM D3960 | 450 | 465 | 469 | 469 |
| Theoretical Spreading Rate (m²/L) | — | 8–13.33 | 7.578–12.63 | 7.578–12.63 | 7.642–12.73 |
| Recommended WFT (µm) (2) | — | 75–125 | 75–125 | 75–125 | 75–125 |
| Recommended DFT (µm) (1) | — | 30–50 | 30–50 | 30–50 | 30–50 |
| Appropriate solvent | — | BMA Thinner PU | BMA Thinner PU | BMA Thinner PU | BMA Thinner PU |
| Solvent ratio by volume (%) | — | 25–35 | 25–35 | 25–35 | 25–35 |
| Gloss Level (%) | ASTM D523 | 70–95 | 35–50 | 25–35 | 0–5 |
| Induction Time (minutes) | — | 5–8 | 5–8 | 5–8 | 5–8 |
| Pot Life at 23 °C (minutes) | — | 60 | 60 | 60 | 60 |
Add 50% hardener by volume.
Before applying BMA PU Lacquer, carry out all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.
For previously painted wooden surfaces, remove paint residues using a scraper or Multichimica Remover to avoid flaking of the new coating in case it is not compatible with the old one. Sand and smooth the surface, then clean it well and remove the sanding dust. Let the surface dry before any primer or sealer application. For new wood, sand the surface and all the edges lightly until smooth. Apply BMA Polyurethane Insulator on oily wooden substrates. Then use NC Putty BMA-PUN to close off, patch and fill all surface imperfections (cracks, holes, pores, etc.). Clean the substrate and let it dry, then make sure the moisture content does not exceed 10%. Sand until smooth using 300-grit sandpaper. Clean it well before any coating application.
Apply a DFT of 40–60 µm of BMA Polyurethane Sealer (SPU102), cross-linked with its hardener BMA-HPU102, directly after preparing, cleaning and drying the surface. Allow the primer sealer to become tack-free before sanding it.
Pour the contents of BMA Polyurethane Lacquer into a larger container, add its corresponding BMA PU Hardener and mix thoroughly. The hardener percentage to the base component is 50% by volume.
If thinning is required, 25–35% of BMA Thinner PU can be used (for air-spray application) to obtain the required viscosity.
Apply BMA Polyurethane Lacquer in a well-ventilated area where the humidity does not exceed 85% and the temperature is not less than 10 °C. The substrate temperature should be at least 3 °C, and the substrate must be dry and free of any residues. Since the coating is a clear system, apply Wood Stain 1BM-STS, then 2 to 3 layers of BMA Sealer. The lacquer can be applied using a spraying system.
The products this coating is specified alongside in the data sheet.
Applied at a DFT of 40–60 µm, cross-linked with its hardener BMA-HPU102, directly after preparing, cleaning and drying the surface.
BMA Polyurethane (PU) Sealer2 to 3 layers applied after Wood Stain 1BM-STS, since the coating is a clear system.
Closes off, patches and fills surface imperfections (cracks, holes, pores, etc.) on new wood.
BMA Nitrocellulose (NC) PuttyAdded at 50% by volume to the base component: 1BM-HPU0100 for the Matt, 30% Glossy and Demi-Matt finishes; 1BM-HPU0200 for the Glossy finish.
25–35% for air-spray application, if thinning is required.
Removes paint residues from previously painted wooden surfaces.
Applied on oily wooden substrates.
Applied first, before the sealer layers, since the coating is a clear system.
BMA Wood StainStore in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.
Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.
Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.
Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.
Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.
Yes. Mix with 50% hardener by volume. Allow an induction time of 5–8 minutes. The pot life is 60 minutes at 23 °C.
BMA Thinner PU, at 25–35% by volume.
Apply it in a well-ventilated area, with humidity no higher than 85%, at a temperature of at least 10 °C, and with a substrate temperature of at least 3 °C.
Tell us your project and volumes — our export team replies with pricing and lead times.