BMA Polyurethane (PU) Lacquer container

BMA Polyurethane (PU) Lacquer

Product code 1BM-LPU0500, 1BM-LPU0400, 1BM-LPU0300, 1BM-LPU0200·Catalog name: PU Lacquer

A two-component polyurethane clear topcoat with weathering resistance, designed to cover surfaces with various levels of chemical and mechanical exposure.

Two-componentSpray

ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015

Key specifications

Gloss level70–95%
Coverage8–13.33m²/L, theoretical
Dry film30–50µm recommended
Touch dry30 minsurface touch dry
Recoat12 hdry to over coat
Pot life60 minafter mixing at 23 °C

What it's used for

Bar and kitchen bench tops
Bathroom vanities
Industrial floors
Wooden furniture

About BMA Polyurethane (PU) Lacquer

BMA Polyurethane (PU) Lacquer is a two-component polyurethane clear topcoat with weathering resistance, designed to cover surfaces with various levels of chemical and mechanical exposure. It has good application properties and must be applied over a dry, contaminant-free polyurethane sealer coat to protect the surface and provide the required gloss level.

Performance

  • Resistance to destructive weathering conditions
  • Various gloss levels
  • Resistance to water and chemical exposure
  • Withstands impact and scratch effects

Available finishes

Matt1BM-LPU0500Hardener 1BM-HPU0100
30% Glossy1BM-LPU0400Hardener 1BM-HPU0100
Demi-Matt1BM-LPU0300Hardener 1BM-HPU0100
Glossy1BM-LPU0200Hardener 1BM-HPU0200

Technical specifications

Data for BMA PU Lacquer:

ParameterNorm / standardGlossyDemi-Matt30% GlossyMatt
Total Solids, by weight (%) ASTM D125952454546
Total Solids, by volume (%) ISO 32334037.8937.8938.21
Viscosity at 25 °C (Poises) ASTM D5623388
Specific Gravity (g/cm³) ASTM D14751.0 ± 0.11.0 ± 0.11.0 ± 0.11.0 ± 0.1
Total Volatile Organic Compound (VOC) (g/L) ASTM D3960450465469469
Theoretical Spreading Rate (m²/L) —8–13.337.578–12.637.578–12.637.642–12.73
Recommended WFT (µm) (2) —75–12575–12575–12575–125
Recommended DFT (µm) (1) —30–5030–5030–5030–50
Appropriate solvent —BMA Thinner PUBMA Thinner PUBMA Thinner PUBMA Thinner PU
Solvent ratio by volume (%) —25–3525–3525–3525–35
Gloss Level (%) ASTM D52370–9535–5025–350–5
Induction Time (minutes) —5–85–85–85–8
Pot Life at 23 °C (minutes) —60606060
  • (1) DFT: Dry Film Thickness
  • (2) WFT: Wet Film Thickness

How much do you need?

Coats
123
You'll need about7.5–12.5 LTheoretical spreading rate 8–13.33 m²/L at the recommended 30–50 µm dry film

Mixing — two-component

Add 50% hardener by volume.

Induction
5–8
Pot life
60 minutes at 23 °C
Thinner
BMA Thinner PU, 25–35% by volume
Hardener
  • 1BM-HPU0100[ "PU Lacquer 30% Glossy", "PU Lacquer Demi matt", "PU Lacquer Matt" ]
  • 1BM-HPU0200[ "PU Lacquer Glossy" ]

How to apply

Before you startHumidity ≤ 85%At least 10 °CSubstrate at least 3 °CWell-ventilated area
1Surface preparation

Before applying BMA PU Lacquer, carry out all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.

2Wooden surfaces

For previously painted wooden surfaces, remove paint residues using a scraper or Multichimica Remover to avoid flaking of the new coating in case it is not compatible with the old one. Sand and smooth the surface, then clean it well and remove the sanding dust. Let the surface dry before any primer or sealer application. For new wood, sand the surface and all the edges lightly until smooth. Apply BMA Polyurethane Insulator on oily wooden substrates. Then use NC Putty BMA-PUN to close off, patch and fill all surface imperfections (cracks, holes, pores, etc.). Clean the substrate and let it dry, then make sure the moisture content does not exceed 10%. Sand until smooth using 300-grit sandpaper. Clean it well before any coating application.

3Priming

Apply a DFT of 40–60 µm of BMA Polyurethane Sealer (SPU102), cross-linked with its hardener BMA-HPU102, directly after preparing, cleaning and drying the surface. Allow the primer sealer to become tack-free before sanding it.

4Mixing

Pour the contents of BMA Polyurethane Lacquer into a larger container, add its corresponding BMA PU Hardener and mix thoroughly. The hardener percentage to the base component is 50% by volume.

5Thinning

If thinning is required, 25–35% of BMA Thinner PU can be used (for air-spray application) to obtain the required viscosity.

6Application

Apply BMA Polyurethane Lacquer in a well-ventilated area where the humidity does not exceed 85% and the temperature is not less than 10 °C. The substrate temperature should be at least 3 °C, and the substrate must be dry and free of any residues. Since the coating is a clear system, apply Wood Stain 1BM-STS, then 2 to 3 layers of BMA Sealer. The lacquer can be applied using a spraying system.

Drying times

  1. Surface Touch Dry30 min
  2. Dry to over coat12 h
  3. Full cure time1 week

Use it with

The products this coating is specified alongside in the data sheet.

Sealer

BMA Polyurethane Sealer (SPU102)

Applied at a DFT of 40–60 µm, cross-linked with its hardener BMA-HPU102, directly after preparing, cleaning and drying the surface.

BMA Polyurethane (PU) Sealer
Sealer

BMA Sealer

2 to 3 layers applied after Wood Stain 1BM-STS, since the coating is a clear system.

Hardener

BMA PU Hardener

Added at 50% by volume to the base component: 1BM-HPU0100 for the Matt, 30% Glossy and Demi-Matt finishes; 1BM-HPU0200 for the Glossy finish.

Thinner

BMA Thinner PU

25–35% for air-spray application, if thinning is required.

Remover

Multichimica Remover

Removes paint residues from previously painted wooden surfaces.

Also

BMA Polyurethane Insulator

Applied on oily wooden substrates.

Also

Wood Stain 1BM-STS

Applied first, before the sealer layers, since the coating is a clear system.

BMA Wood Stain

Packaging, colors & storage

PackagingGallon & Pail kits
ColorsAvailable in clear only.
Shelf life2 years from the manufacturing date.
Storage5 °C – 35 °C, humidity ≤ 85%

Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.

Safety & compliance

Environmental Impact

Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.

Health Hazards

Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.

Safety Precautions

Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.

First Aid Measures

Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.

Certifications

ISO 9001:2015ISO 45001:2018ISO 14001:2015
Technical data sheetTDS 22 · Edition 3
Download PDF
Common questions

Questions about BMA PU Lacquer

You can apply the next coat after 12 hours. The surface is touch dry in 30 minutes.

Yes. Mix with 50% hardener by volume. Allow an induction time of 5–8 minutes. The pot life is 60 minutes at 23 °C.

BMA Thinner PU, at 25–35% by volume.

Apply it in a well-ventilated area, with humidity no higher than 85%, at a temperature of at least 10 °C, and with a substrate temperature of at least 3 °C.

Request a quote for BMA Polyurethane (PU) Lacquer

Tell us your project and volumes — our export team replies with pricing and lead times.