BMA Epoxy Primer container

BMA Epoxy Primer

Product code 1BM-PRE·Catalog name: Primer Epoxy

A two-component, solvent-based epoxy with good hardness and chemical resistance, used as an economical primer to provide chemical protection and mechanical strength against environmental conditions.

Two-componentBrush · Roller · Airless spray

Also in: Metal, Wood

ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015

Key specifications

Coverage7.11–12.8m²/L, theoretical
Dry film50–90µm recommended
Touch dry2 hsurface touch dry
Recoat10–24 hdry to over coat
Pot life2 hafter mixing
VOC318.89g/L

What it's used for

Concrete walls and floors
Marine applications and swimming pools
Chemical, water and power plants
Warehouses and parking areas
Storage tanks
General structural steel

About BMA Epoxy Primer

BMA Epoxy Primer is a two-component, solvent-based epoxy with good hardness and chemical resistance. It is used as an economical primer to provide chemical protection and mechanical strength against environmental conditions. It is suitable for application on well-prepared indoor and outdoor concrete wall and floor substrates, as well as on metallic structures exposed to water immersion and mechanical impacts.

Performance

  • Good resistance to heat, salt water and chemicals
  • Provides effective corrosion protection against environmental exposure
  • Good abrasion and impact resistance
  • Strong adhesion to the surface
  • Capable of withstanding heavy-duty conditions
  • Good non-slip properties
  • High durability
  • Easily maintainable or recoverable
  • Very competitive pricing

Technical specifications

Data for BMA Epoxy Primer cross-linked with 25% by volume of its hardener

ParameterNorm / standardResult
Total Solids, by weight (%) ASTM D125980
Total Solids, by volume (%) ISO 323364.04
Viscosity at 25 °C (Poises) ASTM D56230
Specific Gravity (g/cm³) ASTM D14751.6
Total Volatile Organic Compound (VOC) (g/L) ASTM D3960318.89
Hardener ratio by volume (%) —25
Pot life (hours) —2
Induction time (minutes) —10
Gloss Level (%) —Matt
Appropriate solvent —BMA Thinner Epoxy
Solvent ratio by volume (%) —25

Film thickness & coverage

ParameterNorm / standardResult
Recommended WFT (µm) —75–150
Recommended DFT (µm) —50–90
Theoretical Spreading Rate (m²/L) —7.11–12.8
  • (1) WFT: Wet Film Thickness
  • (2) DFT: Dry Film Thickness

How much do you need?

Coats
123
You'll need about7.8–14.1 LTheoretical spreading rate 7.11–12.8 m²/L at the recommended 50–90 µm dry film

Mixing — two-component

Add 25% hardener by volume.

Induction
10
Pot life
2 hours
Thinner
BMA Thinner Epoxy, 25% by volume
Hardener
  • 1BM-HPE0800

How to apply

Before you startHumidity ≤ 75%5 °C – 35 °CWell-ventilated area
1Surface preparation

Before applying BMA Epoxy Primer, complete all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, agents, dust, dirt, etc.) to avoid the risk of surface failure.

2Metal surfaces

For new steel, clean any oil or grease residues from the surface using SAMA chemical 3 in 1 phosphating additive (1L:35L water). Sand the substrate to Sa 2½ until smooth, then remove all sanding dust and let it dry before applying any primer. For painted steel, remove loose and peeling paint by mechanical methods such as sanding or sandblasting the entire surface until smooth, so the new coating can adhere properly. When the old paint is compatible with the new one, only light sanding is required. Then remove persistent dirt, sanding residues and zinc salts with a detergent solution and water. For non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.), remove corrosion residues and, to promote adhesion of the subsequently applied coatings, use a thin layer (8–10 µm) of BMA Wash Primer to etch the substrate. If the surface is unetched or etching is not possible, sweep or brush blast clean it with a non-metallic abrasive to lightly roughen the surface. Let the surface dry before coating application. To even out surface unevenness, apply BMA putty polyester. For corrosion prevention, prime the cleaned surface directly.

3Concrete surfaces

Prepare the concrete substrate well to avoid any coating defects. For a new surface, ensure the concrete is completely cured for at least 30 days. For both fresh and old concrete, decontamination is required to remove any dust, oil, grease, laitance, fatty acids or other contaminants. Acid etching with Acid Solution is recommended; decontamination can also be done by detergent scrubbing, low-pressure water cleaning or steam. Rinse well with water after acid etching. After cleaning, fill and repair any surface irregularities (cracks, holes and pores) with the cementitious mixture. To prepare the cementitious mixture, first make an SBR Solution by mixing BMA SBR with water (1:5 by volume), then add the SBR Solution to the cement and sand until you reach the desired cementitious mixture. BMA puttypoxy can be used to repair light scratches. Allow the concrete substrate to dry, then check its moisture and pH. Ensure the pH is between 6 and 9, since alkalinity can affect and destroy paint adhesion. Make sure the moisture content does not exceed 4% (by weight); otherwise, the concrete surface is not a good candidate for painting.

4Mixing

Thoroughly mix 25% by volume of the hardener 1BM-HPE0800 with BMA Epoxy Primer. Just before application, let the mixture rest for 10 minutes to allow a complete chemical reaction between the components. Apply within the pot life of 2 hours at ambient temperature.

5Thinning

If thinning is necessary, use a maximum of 15% for brush or roller application, and up to 20% for airless spraying, of BMA Thinner Epoxy to achieve the required viscosity.

6Application

Apply BMA Epoxy Primer in a well-ventilated area where the humidity does not exceed 75% and the temperature is between 5 °C and 35 °C. Do not subject the product to heavy mechanical stress before it is fully cured. Overcoating can be done after 6 hours, for example with BMA Enamopoxy Economic cross-linked with 25% of its hardener 1BM-HPE0800. Let the substrate dry for 3 days before light foot traffic, 5 days before heavy foot traffic and 7 days before vehicle traffic.

  1. Spray: Apply on a clean, dry surface using an airless spraying system within 2 hours.
  2. Brush: Apply on a clean, dry surface using a brush within 2 hours.
  3. Roller: Apply on a clean, dry surface using a roller within 2 hours.

Drying times

  1. Surface Touch Dry2 h
  2. Dry to over coat10–24 h
  3. Full Cure Time3 days

Use it with

The products this coating is specified alongside in the data sheet.

Putty

BMA putty polyester

Evens out surface unevenness on metal.

Putty

BMA puttypoxy

Repairs light scratches in concrete.

Etch primer

BMA Wash Primer

A thin layer (8–10 µm) etches non-ferrous metal (galvanized steel, aluminum, stainless steel, etc.) to promote adhesion.

View in catalog
Etch primer

Acid Solution

Recommended for acid etching of concrete during decontamination; rinse well with water afterward.

Hardener

Hardener 1BM-HPE0800

25% by volume; let the mixture rest 10 minutes before application. Pot life 2 hours at ambient temperature.

Thinner

BMA Thinner Epoxy

If needed: up to 15% for brush or roller, up to 20% for airless spraying.

Topcoat

BMA Enamopoxy Economic

Example overcoat, applied after 6 hours, cross-linked with 25% of its hardener 1BM-HPE0800.

Cleaner

SAMA chemical 3 in 1 phosphating additive

Cleans oil or grease residues from new steel, diluted 1L:35L water.

Also

BMA SBR

Mixed with water (1:5 by volume) to make the SBR Solution for the cementitious repair mixture.

View in catalog

Packaging, colors & storage

PackagingGallon & Pail kits
ColorsAccording to BMA standard colors and RAL shades. Custom colors are available upon request.
Shelf life1 year from the manufacturing date; The hardener has a shelf life of 1 year.
Storage5 °C – 35 °C, humidity ≤ 85%

Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.

Safety & compliance

Environmental Impact

Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.

Health Hazards

Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.

Safety Precautions

Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.

First Aid Measures

Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.

Certifications

ISO 9001:2015ISO 45001:2018ISO 14001:2015
Technical data sheetTDS 193 · Edition 2
Download PDF
Common questions

Questions about BMA Epoxy Primer

You can apply the next coat after 10 to 24 hours. The surface is touch dry in 2 hours.

The theoretical spreading rate is 7.11–12.8 m² per liter at the recommended dry film thickness of 50–90 µm.

Yes. Mix with 25% hardener by volume. Allow an induction time of 10 minutes. The pot life is 2 hours.

BMA Thinner Epoxy, at 25% by volume.

Apply it in a well-ventilated area, with humidity no higher than 75%, and at a temperature between 5 °C and 35 °C.

Request a quote for BMA Epoxy Primer

Tell us your project and volumes — our export team replies with pricing and lead times.