Hardener 1BM-HPU0300
Added at 50% by volume to the base component.

BMA Polyurethane (PU) Primer is a two-component polyurethane primer with fast drying, high durability and superior adhesion properties. It is designed to improve bonding capacity for application on any steel or wooden substrate.
Data for BMA PU Primer:
| Parameter | Norm / standard | Result |
|---|---|---|
| Total Solids, by weight (%) | ASTM D1259 | 70 |
| Total Solids, by volume (%) | ISO 3233 | 53.4 |
| Viscosity at 25 °C (Poises) | ASTM D562 | 30 ± 2 |
| Specific Gravity (g/cm³) | ASTM D1475 | 1.434 |
| Total Volatile Organic Compound (VOC) (g/L) | ASTM D3960 | 424.27 |
| Theoretical Spreading Rate (m²/L) | — | 10.68–17.8 |
| Recommended WFT (µm) (2) | — | 60–100 |
| Recommended DFT (µm) (1) | — | 30–50 |
| Appropriate solvent | — | BMA Thinner PU |
| Solvent ratio by volume (%) | — | 25–30 |
| Hardener Percentage by volume (%) | — | 50 |
| Pot Life (hours) | — | 1 |
| Induction Time (minutes) | — | 3–5 |
Add 50% hardener by volume.
Before applying BMA PU Primer, carry out all necessary pretreatment. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.
Moisture content in the wood should not exceed 10%. Apply a suitable filler to fill cracks and holes. Sand and smooth wooden surfaces. Apply BMA Polyurethane Insulator over the clean surface to isolate the wood before applying any primer.
For optimum performance on metal surfaces, clean the substrate by blast cleaning. Neutralize acid and alkali rust scale with ammonia solution (5%). New steel must be given a surface profile (key) by mechanical or chemical etching. Remove old aged coatings with Multichimica Remover.
Pour the contents of BMA Polyurethane Primer into a larger container, add its corresponding hardener (1BM-HPU0300) and mix thoroughly. The hardener percentage to the base component is 50% by volume.
If thinning is required, use 25 to 30% of BMA Thinner PU with an air-spray system.
Apply BMA Polyurethane Primer in a ventilated area where the temperature is between 5 °C and 35 °C and the relative humidity of the air does not exceed 65%. It must be applied on a clean, dry surface. Apply it by air spray.
The products this coating is specified alongside in the data sheet.
Added at 50% by volume to the base component.
25 to 30% with an air-spray system, if thinning is required.
Removes old aged coatings from steel surfaces.
Applied over the clean wooden surface to isolate the wood before priming.
Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.
Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.
Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.
Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.
Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.
The theoretical spreading rate is 10.68–17.8 m² per liter at the recommended dry film thickness of 30–50 µm.
Yes. Mix with 50% hardener by volume. Allow an induction time of 3–5 minutes. The pot life is 1 hour.
BMA Thinner PU, at 25–30% by volume.
Apply it in a ventilated area, with humidity no higher than 65%, and at a temperature between 5 °C and 35 °C.
Tell us your project and volumes — our export team replies with pricing and lead times.