BMA Emulsion container

BMA Emulsion

Product code 1BM-PAE·Catalog name: Emulsion

BMA Emulsion 1BM-PAE is a vinyl acetate copolymer emulsion paint designed for interior walls and ceilings. This water-based, environmentally friendly coating dries to a smooth, flat finish.

Brush · Roller · Air spray

ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015

Key specifications

Coverage13–16.2m²/L, practical
Touch dry30 minsurface touch dry
Recoat4 hdry to over coat
VOC26g/L

What it's used for

Concrete
Gypsum boards
Plaster
Primed wooden surfaces
  • BMA Emulsion offers excellent adhesion and coverage on a variety of substrates.

About BMA Emulsion

BMA Emulsion 1BM-PAE is a vinyl acetate copolymer emulsion paint designed for interior walls and ceilings. This water-based, environmentally friendly coating provides a smooth, flat finish once dry.

Performance

  • Environmentally friendly formulation
  • Great hiding power
  • Smooth, flat finish
  • Low odor for improved indoor comfort

Technical specifications

Data for BMA Emulsion 1BM-PAE:

ParameterNorm / standardResult
Total Solids, by weight (%) ASTM D236954
Total Solids, by volume (%) ISO 323333.6
Viscosity at 25 °C (KU) ASTM D562120
Specific Gravity (g/cm³) ASTM D14751.5
Total Volatile Organic Compound (VOC) (g/L) ASTM D396026
Practical Spreading Rate (m²/L) —13–16.2
Contrast ratio at 150μm thickness (%) —96
Diluent —Clean Water
Dilution Rate (%) —20–25

How much do you need?

Coats
123
You'll need about6.2–7.7 LPractical spreading rate 13–16.2 m²/L

How to apply

Before you startHumidity ≤ 75%Paint 10 °C – 30 °CWell-ventilated area
1Surface preparation

Carry out all necessary pretreatment before applying BMA Emulsion. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.

2Concrete surfaces

Prepare the concrete substrate well to avoid any coating defects. For new surfaces, make sure the concrete has fully cured for at least 30 days. Fresh and old concrete both need decontamination to remove any dust, oil, grease, laitance, fatty acids or other contaminants. If needed, clean with an ammonia solution followed by thorough rinsing.

3Priming

Prime the non-printed wall with a water-based sealer, putty it to perfection, then undercoat it with BMA solvent-borne or water-borne undercoat.

4Thinning

Use up to 25% water for brush or roller application, and up to 20% water for air-spray application (not recommended).

5Application

Apply BMA Emulsion on a clean, dry surface in a well-ventilated area where the humidity does not exceed 75% and the paint temperature is within 10–30 °C. Otherwise, more thinning will be required, and the extra water could affect the opacity and sag resistance. For the best result, follow the steps below and apply the recommended systems.

6For new surface application
  1. On the clean wall, apply at least one layer of BMA Sealer clear or white.
  2. If the wall is in good condition, apply one layer of BMA Extra Fill Putty 1BM-PUW010, followed by one to two layers of BMA Ultra Fine Putty 1BM-PUW020.
  3. If the wall is in bad condition, apply two to three layers of BMA Extra Fill Putty 1BM-PUW010, followed by one to two layers of BMA Ultra Fine Putty 1BM-PUW020.
  4. Allow a drying period of 12 hours between putty layers.
  5. Rub the surface with 150–180 grit rubbing paper.
  6. Clean the substrate with a soft broom or an air pressure system.
  7. Apply BMA Sealer (1BM-SEW), BMA water-based undercoat (1BM-UNW) or BMA solvent-based undercoat (1BM-UNS), and let the surface dry for 8–12 hours.
  8. Apply one coat of BMA Emulsion as a checking layer to cover any remaining holes or areas not covered by the BMA Putty.
  9. After 24 hours, rub the checking layer with 180–220 grit rubbing paper.
  10. Clean the substrate with a soft broom or an air pressure system.
  11. Finish with two coats of BMA Emulsion after thinning, using a brush, roller or air-spray system (not recommended). Between the two coats, rub the surface with 220-grit rubbing paper.
7For pre-painted surface application
  1. Rub the surface with fine waterproof abrasive paper, then clean it thoroughly.
  2. Apply at least two layers of water-based BMA Putty: at least one layer of BMA Extra Fill Putty 1BM-PUW010 followed by at least one layer of BMA Ultra Fine Putty 1BM-PUW020.
  3. After 12 hours, rub the surface with 150–180 grit rubbing paper.
  4. Continue with the same steps recommended for new surface application.
  5. If the pre-painted surface is in good condition, BMA Emulsion can be applied directly over a water-based paint or a synthetic undercoat.

Drying times

  1. Surface Touch Dry30 min
  2. Dry to over coat4 h
  3. Full cure time48 h

Use it with

The products this coating is specified alongside in the data sheet.

Intermediate

BMA water-based undercoat (1BM-UNW)

Undercoat over the rubbed and cleaned putty, as an alternative to 1BM-SEW or 1BM-UNS; let dry for 8–12 hours.

Intermediate

BMA solvent-based undercoat (1BM-UNS)

Undercoat over the rubbed and cleaned putty, as an alternative to 1BM-SEW or 1BM-UNW; let dry for 8–12 hours.

Sealer

BMA Sealer clear or white

At least one layer on the clean wall as the first step of the new-surface system.

Sealer

BMA Sealer (1BM-SEW)

Applied over the rubbed and cleaned putty, as an alternative to the BMA undercoats; let dry for 8–12 hours.

Putty

BMA Extra Fill Putty 1BM-PUW010

One layer on new walls in good condition, two to three layers on walls in bad condition, and at least one layer on pre-painted surfaces. Allow 12 hours between putty layers.

Putty

BMA Ultra Fine Putty 1BM-PUW020

One to two layers over BMA Extra Fill Putty on new surfaces; at least one layer on pre-painted surfaces.

Packaging, colors & storage

PackagingGallon & Pail kits
ColorsAccording to BMA catalog colors.
Shelf life1 year from the manufacturing date.
Storage5 °C – 35 °C, humidity ≤ 85%

Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.

Safety & compliance

Environmental Impact

Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.

Health Hazards

Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.

Safety Precautions

Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.

First Aid Measures

Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.

Certifications

This product is formulated with low levels of volatile organic compounds (VOC) and is entirely free from lead and other hazardous heavy metals.
Its composition complies with international environmental regulations and health safety standards, ensuring safer application, improved indoor air quality, and reduced environmental impact.
ISO 9001:2015ISO 45001:2018ISO 14001:2015
Technical data sheetTDS 35 · Edition 2
Download PDF
Common questions

Questions about BMA Emulsion

You can apply the next coat after 4 hours. The surface is touch dry in 30 minutes.

The practical spreading rate is 13–16.2 m² per liter.

Clean Water, at 20–25% by volume.

Apply it in a well-ventilated area, with humidity no higher than 75%, and with a paint temperature between 10 °C and 30 °C.

Request a quote for BMA Emulsion

Tell us your project and volumes — our export team replies with pricing and lead times.