BMA Elastic Putty 1BM-EPS
Fills and repairs cracks, holes and pores in cleaned concrete; also used when cementitious walls need to be puttied.

BMA Roof Coating is a water-based, styrene-acrylic modified roof coating that offers long-lasting defense against water leaks, UV radiation, dirt accumulation, ozone, rain and snow.
ISO 9001:2015 · ISO 45001:2018 · ISO 14001:2015
BMA Roof Coating is a water-based, styrene-acrylic modified roof coating designed to provide superior protection for a variety of roofing substrates. It offers long-lasting defense against water leaks, UV radiation, dirt accumulation, ozone, rain and snow. Thanks to its elastomeric properties, 1BM-RCW can stretch and return to its original shape without compromising its protective performance. It is suitable for application on all types of concrete and cementitious roofs, walls and ceilings.
Data for BMA Roof Coating 1BM-RCW:
| Parameter | Norm / standard | Result |
|---|---|---|
| Total Solids, by weight (%) | ASTM D2369 | 56 |
| Total Solids, by volume (%) | ISO 3233 | 46 |
| Total Pigments, by weight (%) | ASTM D3723 | 26 |
| Viscosity at 25 °C (P) | ASTM D562 | 40 |
| Specific Gravity (g/cm³) | ASTM D1475 | 1.2 |
| Dry opacity (Contrast ratio at 150µm WFT) | — | > 0.95 |
| Spreading rate at 200 µm DFT (m²/L) | — | 2.1–2.63 |
| Total Volatile Organic Compound (VOC) (g/L) | ASTM D3960 | 33.93 |
| Appropriate Diluent | — | water |
| Diluent percentage | — | First coat: 80 to 100%; Second coat: 30 to 40%; Third coat: 0 to 10% |
| Recommendation DFT | — | 175-220 microns |
Carry out all necessary pretreatment before applying BMA Roof Coating. The surface should be clean, dry and free of all contaminants (oils, dust, dirt, etc.) to avoid the risk of surface failure.
Prepare the concrete substrate well to avoid any coating defects. For new surfaces, make sure the concrete has fully cured for at least 30 days. Fresh and old concrete both need decontamination to remove any dust, oil, grease, laitance, fatty acids or other contaminants. Acid etching with a hydrochloric acid solution is recommended; decontamination can also be done by detergent scrubbing, low-pressure water cleaning or steam. Rinse well with clean water after acid etching. After cleaning, fill and repair any surface irregularities (cracks, holes and pores) with BMA Elastic Putty 1BM-EPS and allow it to dry. Check the moisture and pH of the substrate. Make sure the pH is between 6 and 9, since alkalinity can affect and destroy paint adhesion, and that the moisture content does not exceed 4% (by weight). Otherwise, the concrete surface is not a good candidate for painting.
Cementitious walls should be unpainted, clean and dry. If the wall needs to be puttied, use BMA Elastic Putty 1BM-EPS.
Apply the first layer of 1BM-RCW with a brush or roller after diluting it with 80 to 100% water, the second layer after diluting it with 30 to 40% water, and the third layer with 0 to 10% water.
Apply BMA Roof Coating in a well-ventilated area where the humidity does not exceed 85% and the temperature is between 10 °C and 35 °C. After thorough cleaning, drying and removal of contamination and dust residues, follow the recommended system below for maximum protection of the substrate.
The products this coating is specified alongside in the data sheet.
Fills and repairs cracks, holes and pores in cleaned concrete; also used when cementitious walls need to be puttied.
Store in undamaged, unopened containers. The product must be kept away from direct sunlight and any sources of heat or flame.
Contains volatile organic compounds (VOCs); avoid release into the environment. Dispose of in accordance with local environmental regulations. Prevent contamination of soil and waterways.
Harmful by inhalation, skin contact, and if swallowed. May cause allergic skin reactions, respiratory irritation, or eye damage. Prolonged exposure may affect the central nervous system.
Use only in well-ventilated areas. Wear appropriate personal protective equipment (PPE) including gloves, goggles, and a respirator. Avoid direct contact with skin and eyes. Do not eat, drink, or smoke while using the product.
Inhalation: Move to fresh air; seek medical attention if symptoms persist. Skin Contact: Wash immediately with soap and water. Remove contaminated clothing. Eye Contact: Rinse cautiously with water for several minutes. Seek medical advice. Ingestion: Do not induce vomiting. Rinse mouth and seek immediate medical assistance.
The theoretical spreading rate is 2.1–2.63 m² per liter at the recommended dry film thickness of 175–220 microns.
water, at First coat: 80 to 100%; Second coat: 30 to 40%; Third coat: 0 to 10% by volume.
Apply it in a well-ventilated area, with humidity no higher than 85%, and at a temperature between 10 °C and 35 °C.
Tell us your project and volumes — our export team replies with pricing and lead times.